Excellent condition unit sold AS IS - price discounted ipad included Can from working office, we just haven't been trained in this unit to properly connect Zeiss VISUPHOR and VISUSCREEN...
Zeiss VISUPHOR and VISUSCREEN Visual Acuity Chart and digital phoropter w/ ipad
The Subjective Refraction Unit from ZEISS combines established procedures with an innovative and intuitive user concept. It allows the user to focus entirely on the patients interactions during vision "testing". The combination of digital phoropter, VISUPHOR® 500 and visual acuity chart system VISUSCREEN 100 offers interaction between extensive test possibilities and fast determination of refraction values.
Preconfigured workflows lets you get right down to work. Choose one of up to six default or customize your own personalized workflow. For each day or for different target groups to match your and your patient’s uniqueness. Take advantage of the new in-built refraction logic and of the supportive control elements & functions, e.g fogging buttons, automatically inserted age-related addition to fasten your examination.
Simple touch control
Simplicity best describes the handling experience of the ZEISS Subjective Refraction Unit. The clearly structured user interface makes working with the ZEISS VISUPHOR 500 & ZEISS VISUSCREEN 100 very easy. With the fully integrated Graphical User Interface, both the phoropter and visual acuity screen can be controlled simultaneously & wireless, even single-handedly, with the optional iPad.
Connectivity is not optional, it is always included. Connecting objective and subjective refraction devices to the practice EMR or PACS is now not only possible but also easy and convenient and enables a completely paperless workflow, eliminates error-prone manual data entry and saves valuable time for staff. Patient data can be stored central and the system allows access anywhere and anytime by staff period. This enables fast working in many places at the same time, e.g. pretest room or doctors office.
ZEISS modern vision testing at its best Skillful determination of best-corrected visual acuity can be time-consuming, requiring operator experience and various fine adjustments. It is well worth the effort when the result is perfect vision correction, a superior viewing experience and highly satisfied patients – as with the digital phoropter VISUPHOR® 500 and the acuity chart system VISUSCREEN 100 from ZEISS. Combining comfort and convenience with speed and efficiency, they offer refraction specialists a sophisticated, modular solution.
Highlights at a glance Silent operation Fast and smooth lens exchanges support efficient vision optimization and final prescription in real time. Simple touch screen control The clearly structured user interface makes working with the ZEISS VISUSCREEN/VISUPHOR very easy. With the fully integrated GUI, both the phoropter and acuity screen can be controlled as one subjective refraction unit. Even single-handedly, with the optional, medical grade panel PC or an iPad. Smart workflow The ZEISS VISUPHOR 500 enables preconfigured workflows. Thereby, settings for each test are optimally adjusted, fully automatically, making standard refraction tests simple and fast. Settings and workflows can also be individually configured in the freestyle mode. Choice of acuity chart systems The ZEISS VISUPHOR 500 digital phoropter is an accessory for the ZEISS VISUSCREEN 100 LCD acuity chart system. It is available either with red/ green separation or with the renowned Polatest® technology from ZEISS. The acuity chart system features over 20 tests for accurately assessing monocular and binocular vision, and can also be operated as stand-alone device if you prefer to work with a trial lens set or a manual phoropter. Headrest control Patient contact with the headrest is continuously monitored and displayed on the screen.
Key benefits for you
• Flexible: Subjective refraction systems from ZEISS are modular and expandable to suit your needs.
• Simple: Acuity charts and phoropter allow easy, intuitive operation via touch-screen interface.
• Efficient: Preconfigured workflows let you get right to work, saving you time preparing refraction tests.
• Connected: You can upload presets from the autorefractor VISUREF® 100 and the digital lensmeter VISULENS® 500 from ZEISS; or directly connect to selected data management systems such as FORUM® from ZEISS.
Made to assist your expertise Simplicity best describes the handling experience of the ZEISS subjective refraction system. Its clear, uncluttered user interface puts the control elements you need directly at the center of focus. The system is operated via touch screen, both with an optional medical grade panel PC or an iPad. Thanks to its WLAN capabilities, cables are kept to a minimum, allowing you to completely concentrate on the refraction procedure. • Select patients from a daily worklist or simply start the refraction • Upload presets from ZEISS autorefractors and lensmeters or access input from a patient database • Choose from a wide range of optotypes and preconfigure your favorite test workflow.